4-pole 40A 415V RCCB circuit breaker electromagnetic type B 30mA residual current circuit breaker

Product Description4 pole 40A 415V 30mA RCCB RCD breaker Residual Current Circuit BreakerTechnical DataModeElectromagneticTypeBRated current In40APoles4PRated voltage Ue4P 415V~Insulation voltage Ui500VRated frequency50/60HzRated residual operation current30mARated residual making and breaking capacity500( In=2540A ) 630 ( In=63

Featured Products

Product Description

4 pole 40A 415V 30mA RCCB RCD breaker Residual Current Circuit Breaker

4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker
Technical Data
Mode
Electromagnetic
Type
B
Rated current In
40A
Poles
4P
Rated voltage Ue
4P 415V~
Insulation voltage Ui
500V
Rated frequency
50/60Hz
Rated residual operation current
30mA
Rated residual making and breaking capacity
500( In=2540A ) 630 ( In=63A )
Short-circuit current Inc
10,000A
Break time under
≤0.1s
Rated impulse withstand voltage (1.5/50) Uimp
4000V
Dielectric test voltage at ind. Freq. FOR 1min
2.5kV
Electrical life
2000 cycles
Mechanical life
4000 cycles
Installation
Contact position indicator
Yes
Protection degree
IP 20
Ambient temperature ( with daily average ≤35ºC)
-5ºC~+40ºC
Storage temperature
-25ºC~+70ºC
Terminal connection type
Cable/ Pin-type busbar/U-type busbar
Terminal size top/bottom for cable
25mm²18-3AWG
Terminal size top/bottom for
25mm²18-3AWG
Tightening torque
2.5Nm 22In-bls
Mounting
On DIN rail EN60715 ( 35mm ) by means of fast clip device
Connection
From top to bottom
4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker
Introduction
A Residual Current Circuit Breakers is another different class of Circuit Breakers. A Residual Current Circuit Breaker (RCCB) is essentially a current sensing device used to protect a low voltage circuit in case of a fault. It contains a switch device that switches off whenever a fault occurs in the connected circuit.

Purpose of RCCB

Residual Current Circuit Breakers are aimed at protecting an individual from the risks of electrical shocks, electrocution andfires that are caused due to faulty wiring or earth faults.

RCCB is particularly useful in situations where there is a sudden earth fault occurring in the circuit.
 
In such situation, in absence of an RCCB in the circuit, an earth fault may occur and the person is at the risk of receiving an
electrical shock.

However, if the same circuit is protected with RCCB, it will trip the circuit in fraction of a second thus preventing the person
from receiving an electrical shock. Therefore, it is a good and safe practice to install RCCB in your electrical circuit.

How does it Protect?

As explained above, RCCB is meant for protection from earth faults and associated risk to human life such as electrical shocks.

The underlying fundamental principle behind operation of RCCB is that in ideal situations the current flowing in to the circuitthrough live (hot) wire should be same as the returning current from the neutral.
 
In case of an earth fault, the current finds a passage to earth through accidental means (such as accidental contact with an openwire etc.). As a result the returning current from neutral is reduced. This differential in the current is also known as "Residual Current".
 
RCCB is designed such way that it continuously senses and compares for difference (residual current value) in current values between the live and neutral wires. Any small change in the current value on account of such event would trigger the RCCB to trip off the circuit.
Product Package
4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker
 
 


Producing
4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker

Packing
4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker

Shipping
4 Pole 40A 415V RCCB Breaker Electromagnetic Type B 30mA Residual Current Circuit Breaker


FAQ

 

Q1. What is your terms of packing?

A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent,
we can pack the goods in your branded boxes after getting your authorization letters.

 

Q2. What is your terms of payment?

A: 100% T/T before payment. Or T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages
before you pay the balance.

 

Q3. What is your terms of delivery?

A: FOB, CFR, CIF, DDU.

 

Q4. How about your delivery time?

A: Generally, it will take 3 to 25 days after receiving your advance payment. The specific delivery time depends
on the items and the quantity of your order.

 

Q5. Can you produce according to the samples?

A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

 

Q6. What is your sample policy?

A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and
the courier cost.

 

Q7. Do you test all your goods before delivery?

A: Yes, we have 100% test before delivery

 

Q8: How do you make our business long-term and good relationship?

A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them,
no matter where they come from.
















 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours