Dam1-125 Isomax Power Circuit Breaker

DAM1-1251P,2P,3P,4P 400V/415V Moulded case circuit breaker high quality with ASTA,KEMA,SEMKO,CE,CB,ROHS certificateIntroductionThe DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at short circuits, overload, inadmissible bucking as well as operational actuation and tripping of

Featured Products

DAM1-125


Dam1-125 Isomax Power Circuit Breaker


1P,2P,3P,4P 400V/415V Moulded case circuit breaker high quality with ASTA,KEMA,SEMKO,CE,CB,ROHS certificate


Introduction
The DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at short circuits, overload, inadmissible bucking as well as operational actuation and tripping of electric circuit parts. They are designed for use in electric units having the operative voltage limited to 400V per rated current from 12,5 to 1600A. 

They correspond to the requirements of EN 60947-1, EN 60947-2 

Thermal-Magnetic Circuit Breakers:
Thermal protection function:(For protection under over load conditions) 
Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing through the breaker. Because, increase of current means increase of heat. In this way, over current protection function of the breaker is fulfilled by bimetal at load currents higher than the rated current

Magnetic protection function (For protection under short circuit
conditions)
Another function of the breaker is to protect the connected circuit against short circuits. Short circuit may occur as a result of contact of phases with each other or contact of phase-ground. Since a very high current shall pass through the cables in case of short circuit, system energy should be broken in a shorter time due to thermal protection. Breaker should perform instant opening to protect load it is connected to. The part fulfilling this function is a mechanical opening mechanism that operates with magnetization caused by the magnetic
area formed by the short circuit current

 

Advantages

 
  • Easy independent installation of auxiliary devices:
    • Alarm contact;
    • Auxiliary contact;
    • Under voltage release;
    • Shunt release;
    • Handle operating mechanism;
    • Electrical operating mechanism;
    • Plug-in device;
    • Draw-out device;.
  • Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting onto an installation panel.
  • With the help of special clamp 125 and 160 units can be installed onto a DIN-rail.
  • Weight and dimensions of these circuit breakers are by 10-20% less than that suggested by other home manufacturers. This fact provides for mounting smaller boxes and panels. Besides, small dimensions make it possible to change old circuit breakers to DAM1.

Application
Moulded case circuit breakers are low-voltage circuit breakers. They meet the installation needs of small users all the way to large industrial substations and power distribution systems. They are commonly applied in steel mills, oil platforms, hospitals, railway systems, airports, computing centers, office buildings, convention centers, theaters, skyscrapers, and other large scale structures.

  
 
Electrical parameters of DAM1 MCCB molded case circuit breaker
 
Thermal-magnetic fixed type MCCB        
PhotoModelcode  Icu (KA)Ics (KA)Rated Current
-In
Ui(V)Ue(V)PoleUimp(V)
 DAM1-160B2518.7510 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160A500V230V1P10000
N3627
 DAM1-200B2518.7510 - 12,5 - 16 - 20 - 25 - 32 - 40 - 50 - 63- 80 - 100 - 125-160(200)A750V400V2P10000
N3627
 DAM1-125B2512.510 - 12,5 - 16 - 20 - 25 - 32(30) - 40 - 50 - 63(60) - 80 - 100 - 125A750V400V3P / 4P10000
N3517.5
S5037.5
 DAM1-160B2512.510- 12,5-16-20 - 25 - 32 - 40  - 50 - 63 - 80 - 100 -125 - 160(150)A750V400/415V3P / 4P8000
N3526.25
S5037.5
 DAM1-250N3526.2563 - 80-100-125 - 160(180) -  200(225) - 250(320)A750V400/415V3P /4P8000
S5037.5
H6548.75
G8551
 DAM1-630(400)N3526.25250 - 315 (350)- 400 - 500  - 630A750V400/415V3P /4P8000
S5037.5
H7052.5
G8552.5
 DAM1-800N3535400 - 500 - 630 (700)- 800 -1000A750V400/415V3P /4P8000
S5037.5
H7052.5
G8552.5
 DAM1-1600S6550800 -1000 - 1250 - 1600A750V400V3P / 4P8000
H8550
G10050
·Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)
·Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)
ON/I Position: It indicates that contacts of the breaker are closed. In this position, the breaker lever is in the top position
TRIP Position: It indicates that the breaker is opened due to any failure (over load or short circuit). In this case, breaker lever is in the middle position between ON and OFF positions. In order to take the breaker, which is in trip position, to ON position; push the breaker lever downwards as shown by the OFF sign
Breaker shall be set with "click" sound.After that, pull the lever as shown by ON sign to close the breaker 
OFF/0 Position: It indicates that contacts of the breaker are open. In this way, the breaker lever is in the bottom position.

Physical parameters of DAM1-125 MCCB molded case circuit breaker
 
Category (EN 60947-2/IEC 60947-2)Endurance 
ModelPoleDielectric Propery (V)lonization distance                                                                                                              (mm)Total CyclesElectrical LifeMechanical LifeMain circuitAuxiliary circuit
DAM1-1601P2500≤30/020000300017000A/0AC-15
DAM1-2002P2500≤30/015000250012500A/0AC-15
DAM1-1253P / 4P2500≤30/0800010007000A/0AC-15
DAM1-1603P / 4P3000≤30/0800010007000A/0AC-15
DAM1-2503P /4P3000≤30/0800010007000A/BAC-15
DAM1-630(400)3P /4P3000≤60/0500010004000A/BAC-15
DAM1-8003P /4P3000≤80/0500010004000A/BAC-15
DAM1-16003P / 4P3000≤80/030005002500A/BAC-15



Size of MCCB molded case circuit breaker


 
ModelPoleOutline dimension
(LXWXH)
DAM1-1601P120x30x70mm
DAM1-2002P120x60x70mm
DAM1-1253P120x76x70mm
 4P120x101x70mm
DAM1-1603P120x90x70mm
 4P120x120x70mm
DAM1-2503P170x105x103.5mm
 4P170x140x103.5mm
DAM1-630(400)3P254x140x103.5mm
 4P254x184x103.5mm
DAM1-8003P268x210x103.5mm
 4P268x280x103.5mm
DAM1-16003P410x210x138.5mm
 4P410x280x138.5mm


Working principle
The main contact of the molded case circuit breaker is manual manipulation or electric closing. After the main contact is closed, the free release mechanism locks the main contact into the closing position. The over current trip coil and the thermal trip element are connected in series with the main circuit. The under voltage release coil and the power supply are connected in parallel.

Dam1-125 Isomax Power Circuit Breaker
 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours