L7 2p Solar PV DC 415V MCB 15A Electric Mini Circuit Breaker

1.Using Environmental ConditionsL7-63 product is suitable for sea dials altitude 2000 meters and below above 2000 meters need to drop the easy to use and other special requi-rements please and contact the manufacturer: ambient air temperature 25 degrees to 40 degrees, 24 hours average temperature does not exceed 35 degrees;

Featured Products

1.Using Environmental Conditions

L7-63 product is suitable for sea dials altitude 2000 meters and below above 2000 meters need to drop the easy to use and other special requi-rements please and contact the manufacturer: ambient air temperature 25 degrees to 40 degrees, 24 hours average temperature does not exceed 35 degrees; when the ambient air temperature of more than 40 degrees or below-25 degrees, please contact the manufacturer; can withstand humid air, salt fog and mold affect three defenses( Type).

Apply to the unipolar volume constant DC voltage does not exceed 250VDC. Diode does not exceed 500VDC triode does not exceed 800VDC and a quadrupole does not exceed 1000VDC 1200VDC, rated current 1-63A, rated insulation 500v voltage line, used on buildings and similar places the line facilities of over current protection, can also be used in less frequent break operation. The circuit breaker has small volume, breaking capacity, arcing distance is short, fast closing and installation is convenient wait for a characteristic. This product applicable to non professionals use and do not need to maintain. L7-63 series DC circuit breaker above DC800V products with internal edge connection mode, so that the same user connection mode and 2p products, more convenient for users to install.

2.Electrical Parameters

The Number Of Poles

1P

2P

3P

4P

Rated Voltage Ue(V)

DC250V

DC500V

DC800V

DC1000V/DC1200V

Rated Current In(A)

Curve B: 1,2,3,4,5,6,10,16,20,25,32,40,50,63

Rated Short Circuit Capacity Icn(KA)(T=4ms)

Curve C: 1,2,3,4,5,6,10,16,20,25,32,40,50,63

Instantaneous Release Form

6

Rated Impulse Withstand Voltage Uimp( KV)

B,C

Rated Insulation Voltage Ui

4

Life(time)

1200

Use Environment

With a load of 10000 times. not with a load of 20000 times

Can Take Accessories

Ambient temperature: -25ºC to 40ºC

Maximum Wiring Capacity

Auxiliary switch, alarm switch, shunt25mm²

Meet The Standards

EC60947-2, IEC60898-2, GB10963.2, GB14048.2

3.Outline Dimension
L7 2p Solar PV DC 415V MCB 15A Electrical Mini Circuit Breaker
 

L7 2p Solar PV DC 415V MCB 15A Electrical Mini Circuit Breaker

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours